Radiotherapy & Oncology
Volume 49, Issue 2 , Pages 191-196, November 1998

Monte Carlo calculation of the dose distributions of two 106Ru eye applicators

  • Alberto Sánchez-Reyes

      Affiliations

    • Servicio de Oncología Radioterápica, Hospital Clínic Universitari de Barcelona, Villarroel 170, 08036Barcelona, Spain
    • Corresponding Author InformationCorresponding author
  • ,
  • Juan José Tello

      Affiliations

    • Facultat de Medicina, Universitat de Barcelona, Villarroel 170, 08036Barcelona, Spain
  • ,
  • Benjamín Guix

      Affiliations

    • Facultat de Medicina, Universitat de Barcelona, Villarroel 170, 08036Barcelona, Spain
  • ,
  • Francesc Salvat

      Affiliations

    • Facultat de Física (ECM), Universitat de Barcelona, Societat Catalana de Física (IEC), Diagonal 647, 08028, Barcelona, Spain

Received 4 November 1997; received in revised form 18 June 1998; accepted 14 August 1998.

Abstract 

Background and purpose: Beta emitting 106Ru applicators are widely used to treat choroidal melanoma. In view of the importance of clinical applications of this radioisotope and the relative lack of knowledge of the dose distributions, three-dimensional dose maps of two concave applicators were calculated by means of Monte Carlo simulation.

Materials and methods: Simulations of small CCA and CCB concave applicators manufactured by Bebig were performed using the Monte Carlo code PENELOPE, which allows the description of the structure (geometry and materials) of the applicator in detail. Electrons are emitted from the 106Ru nuclei isotropically, with initial energy randomly sampled from the corresponding Fermi spectra and with initial positions uniformly distributed on the radioactive layer. Primary electrons, as well as the produced δ-rays, are assumed to be absorbed in the medium when they slow down to an energy of 70 keV. Bremsstrahlung photons with energies larger than 7 keV are also simulated. The simulation code has been run on a 166 MHz PENTIUM PC.

Results: Three-dimensional dose distributions produced by the CCA and CCB applicators in a water sphere, concentric with the applicator, were evaluated. To minimize the magnitude of statistical uncertainties, advantage has been taken of the cylindrical symmetry of the problem. The relative depth-dose (along the symmetry axis of the applicator) was also evaluated from the applicator surface up to distances larger than 1 cm, with statistical uncertainties of a few percent. Results compare well with data supplied by the manufacturer.

Conclusions: We have performed accurate Monte Carlo calculations of three-dimensional dose distributions from CCA and CCB 106Ru applicators. The results, presented in the form of two-dimensional maps, depth-dose distributions along the symmetry axis and lateral dose profiles, provide a detailed description of the dose delivered in treatments of choroidal melanoma.

Keywords: Monte Carlo, Dosimetry, Brachytherapy, Eye melanoma, Ruthenium-106

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0167-8140(98)00095-4

doi:10.1016/S0167-8140(98)00095-4

Radiotherapy & Oncology
Volume 49, Issue 2 , Pages 191-196, November 1998