Radiotherapy & Oncology
Volume 96, Issue 3 , Pages 317-324, September 2010

Physical radiotherapy treatment planning based on functional PET/CT data

  • Daniela Thorwarth

      Affiliations

    • Section for Biomedical Physics, University Hospital for Radiation Oncology, Tübingen, Germany
    • Corresponding Author InformationCorresponding author. Address: Section for Biomedical Physics, University Hospital for Radiation Oncology, Hoppe-Seyler-Str. 3, 72076 Tübingen, Germany.
  • ,
  • Xavier Geets

      Affiliations

    • Department of Radiation Oncology, St-Luc University Hospital, Brussels, Belgium
  • ,
  • Marta Paiusco

      Affiliations

    • Medical Physics Department, Arcispedale Santa Maria Nuova, Reggio Emilia, Italy

Received 9 July 2010; received in revised form 12 July 2010; accepted 13 July 2010. published online 02 August 2010.

Abstract 

Positron emission tomography (PET) provides molecular information about the tumor microenvironment in addition to anatomical imaging. Hence, it seems to be highly beneficial to integrate PET data into radiotherapy (RT) treatment planning. Functional PET images can be used in RT planning following different strategies, with different orders of complexity. In a first instance, PET imaging data can be used for better target volume delineation. A second strategy, dose painting by contours (DPBC), consists of creating an additional PET-based target volume which will then be treated with a higher dose level. In contrast, dose painting by numbers (DPBN) aims for a locally varying dose prescription according to the variation of the PET signal. For both dose painting approaches, isotoxicity planning strategies should be applied in order not to compromise organs at risk compared to conventional modern RT treatment.

In terms of physical dose painting treatment planning, several factors that may introduce limitations and uncertainties are of major importance. These are the PET voxel size, uncertainties due to image acquisition and reconstruction, a reproducible image registration, inherent biological uncertainties due to biological and chemical tracer characteristics, accurate dose calculation algorithms and radiation delivery techniques able to apply highly modulated dose distributions. Further research is necessary in order to investigate these factors and their influence on dose painting treatment planning and delivery thoroughly.

To date, dose painting remains a theoretical concept which needs further validation. Nevertheless, molecular imaging has the potential to significantly improve target volume delineation and might also serve as a basis for treatment alteration in the future.

Keywords: Functional PET/CT imaging, RT treatment planning, Dose calculation, Dose painting by contours, Dose painting by numbers

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0167-8140(10)00403-2

doi:10.1016/j.radonc.2010.07.012

Radiotherapy & Oncology
Volume 96, Issue 3 , Pages 317-324, September 2010