Radiotherapy & Oncology
Volume 93, Issue 3 , Pages 625-632 , December 2009

Modulated electron radiotherapy treatment planning using a photon multileaf collimator for post-mastectomized chest walls

  • Francisco Javier Salguero

      Affiliations

    • Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Spain
    • Hospital Universitario Virgen Macarena, Sevilla, Spain
  • ,
  • Bianey Palma

      Affiliations

    • Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Spain
    • Hospital Universitario Virgen Macarena, Sevilla, Spain
  • ,
  • Rafael Arrans

      Affiliations

    • Hospital Universitario Virgen Macarena, Sevilla, Spain
  • ,
  • Joan Rosello

      Affiliations

    • Servicio de Radiofísica-ERESA, Hospital General Universitario de Valencia, Spain
  • ,
  • Antonio Leal

      Affiliations

    • Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Spain
    • Hospital Universitario Virgen Macarena, Sevilla, Spain
    • Corresponding Author InformationCorresponding author. Address: Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Hospital Universitario Virgen Macarena, Sevilla, Spain.

Received 12 February 2009 ,Revised 13 August 2009 ,Accepted 13 August 2009.

References 

  1. Hooning MJ, Aleman BM, van Rosmalen AJ, Kuenen MA, Klijn JG, van Leeuwen FE. Cause-specific mortality in long-term survivors of breast cancer: a 25-year follow-up study. Int J Radiat Oncol Biol Phys. 2006;64:1081–1091
  2. Vagane R, Danielsen T, Fossa SD, Lokkevik E, Olsen DR. Late regional density changes of the lung after radiotherapy for breast cancer. Radiother Oncol. 2009;90:148–152
  3. Gez E, Assaf N, Bar-Deroma R, Rosenblatt E, Kuten A. Postmastectomy electron-beam chest-wall irradiation in women with breast cancer. Int J Radiat Oncol Biol Phys. 2004;60:1190–1194
  4. Kirova YM, Campana F, Fournier-Bidoz N, et al. Postmastectomy electron beam chest wall irradiation in women with breast cancer: a clinical step toward conformal electron therapy. Int J Radiat Oncol Biol Phys. 2007;69:1139–1144
  5. Pierce LJ, Butler JB, Martel MK, et al. Postmastectomy radiotherapy of the chest wall: dosimetric comparison of common techniques. Int J Radiat Oncol Biol Phys. 2002;52:1220–1230
  6. Korreman SS, Pedersen AN, Nottrup TJ, Specht L, Nystrom H. Breathing adapted radiotherapy for breast cancer: comparison of free breathing gating with the breath-hold technique. Radiother Oncol. 2005;76:311–318
  7. Gagel B, Demirel C, Kientopf A, et al. Active breathing control (ABC): determination and reduction of breathing-induced organ motion in the chest. Int J Radiat Oncol Biol Phys. 2007;67:742–749
  8. Kestin LL, Sharpe MB, Frazier RC, et al. Intensity modulation to improve dose uniformity with tangential breast radiotherapy: initial clinical experience. Int J Radiat Oncol Biol Phys. 2000;48:1559–1568
  9. Vicini FA, Sharpe M, Kestin L, et al. Optimizing breast cancer treatment efficacy with intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys. 2002;54:1336–1344
  10. Asell M, Hyodynmaa S, Gustafsson A, Brahme A. Optimization of 3D conformal electron beam therapy in inhomogeneous media by concomitant fluence and energy modulation. Phys Med Biol. 1997;42:2083–2100
  11. Ma CM, Ding M, Li JS, Lee MC, Pawlicki T, Deng J. A comparative dosimetric study on tangential photon beams, intensity-modulated radiation therapy (IMRT) and modulated electron radiotherapy (MERT) for breast cancer treatment. Phys Med Biol. 2003;48:909–924
  12. Ravindran BP, Singh IR, Brindha S, Sathyan S. Manual multi-leaf collimator for electron beam shaping–a feasibility study. Phys Med Biol. 2002;47:4389–4396
  13. Gauer T, Albers D, Cremers F, Harmansa R, Pellegrini R, Schmidt R. Design of a computer-controlled multileaf collimator for advanced electron radiotherapy. Phys Med Biol. 2006;51:5987–6003
  14. Al-Yahya K, Verhaegen F, Seuntjens J. Design and dosimetry of a few leaf electron collimator for energy modulated electron therapy. Med Phys. 2007;34:4782–4791
  15. Jansson T, Lindman H, Nygard K, et al. Radiotherapy of breast cancer after breast-conserving surgery: an improved technique using mixed electron-photon beams with a multileaf collimator. Radiother Oncol. 1998;46:83–89
  16. du Plessis FC, Leal A, Stathakis S, Xiong W, Ma CM. Characterization of megavoltage electron beams delivered through a photon multi-leaf collimator (pMLC). Phys Med Biol. 2006;51:2113–2129
  17. Klein EE, Vicic M, Ma CM, Low DA, Drzymala RE. Validation of calculations for electrons modulated with conventional photon multileaf collimators. Phys Med Biol. 2008;53:1183–1208
  18. Klein EE, Mamalui-Hunter M, Low DA. Delivery of modulated electron beams with conventional photon multi-leaf collimators. Phys Med Biol. 2009;54:327–339
  19. Jin L, Ma CM, Fan J, et al. Dosimetric verification of modulated electron radiotherapy delivered using a photon multileaf collimator for intact breasts. Phys Med Biol. 2008;53:6009–6025
  20. Mohan R, Antolak J. Monte Carlo techniques should replace analytical methods for estimating dose distributions in radiotherapy treatment planning. Med Phys. 2001;28:123–126
  21. Chetty IJ, Curran B, Cygler JE, et al. Report of the AAPM Task Group No. 105: issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med Phys. 2007;34:4818–4853
  22. Seuntjens J, Van der Plaetsen A, Thierens H, Piessens M. Comparison of measured and calculated dose distributions in lung after electron beam treatment of the chest wall. Med Phys. 1994;21:1959–1968
  23. Coleman J, Park C, Villarreal-Barajas JE, Petti P, Faddegon B. A comparison of Monte Carlo and Fermi–Eyges–Hogstrom estimates of heart and lung dose from breast electron boost treatment. Int J Radiat Oncol Biol Phys. 2005;61:621–628
  24. Ding GX, Cygler JE, Yu CW, Kalach NI, Daskalov G. A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm. Int J Radiat Oncol Biol Phys. 2005;63:622–633
  25. Fragoso M, Pillai S, Solberg TD, Chetty IJ. Experimental verification and clinical implementation of a commercial Monte Carlo electron beam dose calculation algorithm. Med Phys. 2008;35:1028–1038
  26. Cygler JE, Lochrin C, Daskalov GM, et al. Clinical use of a commercial Monte Carlo treatment planning system for electron beams. Phys Med Biol. 2005;50:1029–1034
  27. Su FC, Liu Y, Stathakis S, Shi C, Esquivel C, Papanikolaou N. Dosimetry characteristics of GAFCHROMIC EBT film responding to therapeutic electron beams. Appl Radiat Isot. 2007;65:1187–1192
  28. Andreo P, Almond PR, Mattsson O, Nahum AE, Roos M. The use of plane-parallel ionization chambers in high-energy electron and photon beams. An international code of practice for dosimetry. TRS 381. International Atomic Energy Agency; 1995.
  29. Andreo P, Burns D, Hohlfeld K et al. Absorbed dose determination in external beam radiotherapy. TRS 398. International Atomic Energy Agency; 2000.
  30. Struikmans H, Warlam-Rodenhuis C, Stam T, et al. Interobserver variability of clinical target volume delineation of glandular breast tissue and of boost volume in tangential breast irradiation. Radiother Oncol. 2005;76:293–299
  31. Li XA, Tai A, Arthur DW, et al. Variability of target and normal structure delineation for breast cancer radiotherapy: an RTOG Multi-Institutional and Multiobserver Study. Int J Radiat Oncol Biol Phys. 2009;73:944–951
  32. Rogers DWO, Ma CM, Walters B, Ding GX, Sheikh-Bagheri D, Zhang G. BEAMnrc Users Manual. Ionizing Radiation Standards National Research Council of Canada, Ottawa, K1A OR6; 2002.
  33. Walters B, Kawrakov I, Rogers DWO. DOSXYZnrc Users Manual. Ionizing Radiation Standards National Research Council of Canada, Ottawa, K1A OR6; 2005.
  34. Leal A, Sanchez-Doblado F, Arrans R, et al. Monte Carlo simulation of complex radiotherapy treatments. Comput Sci Eng. 2004;6:60–68
  35. Chow JC, Grigorov GN. Electron radiotherapy: a study on dosimetric uncertainty using small cutouts. Phys Med Biol. 2007;52:N1–N11
  36. Snyman J. Practical mathematical optimization: an introduction to basic optimization theory and classical and new gradient-based algorithms. Applied optimization. vol. 97. Springer; 2005;
  37. Ma CM, Price RA, Li JS, et al. Monitor unit calculation for Monte Carlo treatment planning. Phys Med Biol. 2004;49:1671–1687
  38. Lax I. Accuracy in clinical electron beam dose planning using pencil beam algorithms. Radiother Oncol. 1987;10:307–319

PII: S0167-8140(09)00458-7

doi: 10.1016/j.radonc.2009.08.021

Radiotherapy & Oncology
Volume 93, Issue 3 , Pages 625-632 , December 2009