Radiotherapy & Oncology
Volume 93, Issue 1 , Pages 1-7 , October 2009

Image quality and stability of image-guided radiotherapy (IGRT) devices: A comparative study

  • Markus Stock

      Affiliations

    • Department of Radiotherapy, Medical University Vienna, Austria
    • Corresponding Author InformationCorresponding author. Address: Division of Medical Radiation Physics, Department of Radiotherapy, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria.
  • ,
  • Marlies Pasler

      Affiliations

    • Department of Radiotherapy, Medical University Vienna, Austria
  • ,
  • Wolfgang Birkfellner

      Affiliations

    • Center for Biomedical Engineering and Physics, Medical University Vienna, Austria
  • ,
  • Peter Homolka

      Affiliations

    • Center for Biomedical Engineering and Physics, Medical University Vienna, Austria
  • ,
  • Richard Poetter

      Affiliations

    • Department of Radiotherapy, Medical University Vienna, Austria
  • ,
  • Dietmar Georg

      Affiliations

    • Department of Radiotherapy, Medical University Vienna, Austria

Received 5 February 2009 ,Revised 29 May 2009 ,Accepted 16 July 2009.

References 

  1. Oldham M, Létourneau D, Watt L, et al. Cone-beam-CT guided radiation therapy: a model for on-line application. Radiother Oncol. 2005;75:271–278
  2. Létourneau D, Martinez AA, Lockman D, et al. Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients. Int J Radiat Oncol Biol Phys. 2005;62:1239–1246
  3. Smitsmans MH, de Bois J, Sonke JJ, et al. Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy. Int J Radiat Oncol Biol Phys. 2005;63:975–984
  4. Jaffray DA, Drake DG, Moreau M, et al. A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets. Int J Radiat Oncol Biol Phys. 1999;45:773–789
  5. Siewerdsen JH, Jaffray DA. Cone-beam computed tomography with a flat-panel imager: effects of image lag. Med Phys. 1999;26:2635–2647
  6. Feldkamp LA, Davis LC, Kress JW. Practical cone-beam algorithm. J Opt Soc Am A. 1984;1:612–619
  7. Mackie TR, Kapatoes J, Ruchala K, et al. Image guidance for precise conformal radiotherapy. Int J Radiat Oncol Biol Phys. 2003;56:89–105
  8. Meeks SL, Harmon JF, Langen KM, et al. Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit. Med Phys. 2005;32:2673–2681
  9. Oelfke U, Tücking T, Nill S, et al. Linac-integrated kV-cone beam CT: technical features and first applications. Med Dosim. 2006;31:62–70
  10. Stützel J, Oelfke U, Nill S. A quantitative image quality comparison of four different image guided radiotherapy devices. Radiother Oncol. 2008;86:20–24
  11. Sharpe M, Brock KK. Quality assurance of serial 3D image registration, fusion, and segmentation. Int J Radiat Oncol Biol Phys. 2008;71:33–37
  12. Balter JM, Antonuk LE. Quality assurance for kilo- and megavoltage in-room imaging and localization for off- and online setup error correction. Int J Radiat Oncol Biol Phys. 2008;71:48–52
  13. Saw CB, Yang Y, Li F, et al. Performance characteristics and quality assurance aspects of kilovoltage cone-beam CT on medical linear accelerator. Med Dosim. 2007;32:80–85
  14. Nijkamp J, Pos FJ, Nuver TT, et al. Adaptive radiotherapy for prostate cancer using kilovoltage cone-beam computed tomography: first clinical results. Int J Radiat Oncol Biol Phys. 2008;70:75–82
  15. Létourneau D, Wong R, Moseley D, et al. Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: image quality and system performance. Int J Radiat Oncol Biol Phys. 2007;67:1229–1237
  16. Yoo S, Kim GY, Hammoud R, et al. A quality assurance program for the on-board imager®. Med Phys. 2006;33:4431–4447
  17. Bissonnette JP, Moseley DJ, Jaffray D. A quality assurance program for image quality of cone-beam CT guidance in radiation therapy. Med Phys. 2008;35:1807–1815
  18. Sykes JR, Lindsay R, Dean CJ, et al. Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR™ Penta-Guide pantom. Phys Med Biol. 2008;53:5275–5293
  19. Mail N, Moseley DJ, Siewerdsen JH, et al. The influence of bowtie filtration on cone-beam CT image quality. Med Phys. 2009;36:22–32
  20. Lehmann J, Perks J, Semon S, et al. Commissioning experience with cone-beam computed tomography for image-guided radiation therapy. J Appl Clin Med Phys. 2007;8:21–36
  21. White DR, Speller RD, Taylor PM. Evaluating performance characteristics in computerized tomography. Br J Radiol. 1981;54:221–231

PII: S0167-8140(09)00430-7

doi: 10.1016/j.radonc.2009.07.012

Radiotherapy & Oncology
Volume 93, Issue 1 , Pages 1-7 , October 2009