Initial validations for pursuing irradiation using a gimbals tracking system
References
- The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys. 2006;33:3874–3900
- Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy. Int J Radiat Oncol Biol Phys. 2006;64:1229–1236
- . Effects of motion on the total dose distribution. Semin Radiat Oncol. 2004;14:4151
- . Evaluation of the validity of a convolution method for incorporating tumour movement and set-up variations into the radiotherapy treatment planning system. Phys Med Biol. 2000;45:923931
- The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: reduction of respiratory tumor movement, evaluation of the daily setup accuracy. Int J Radiat Oncol Biol Phys. 2001;50:889898
- A new irradiation system for lung cancer combining linear accelerator, computed tomography, patient self-breath-holding, patient-directed beam-control without respiratory monitoring devices. Int J Radiat Oncol Biol Phys. 2003;56:1420
- The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys. 1999;44:911919
- Irradiation synchronized with respiration gate. Int J Radiat Oncol Biol Phys. 1989;17:853857
- . Respiration gated radiotherapy treatment: a technical study. Phys Med Biol. 1996;41:8391
- Image guided respiratory gated hypofractionated Stereotactic Body Radiation Therapy (H-SBRT) for liver, lung tumors: initial experience. Acta Oncol. 2006;45:881889
- . Tracking moving organs in real time. Semin Radiat Oncol. 2004;14:91100
- Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. Med Phys. 2005;32:942951
- . Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study. Phys Med Biol. 2005;50:4021–4033
- Development of a four-dimensional image-guided radiotherapy system with a gimbaled X-ray head. Int J Radiat Oncol Biol Phys. 2006;66:271278
- Development of a three-dimensionally movable phantom system for dosimetric verifications. Med Phys. 2008;35:1643–1650
- . The fitting of time series models. Rev Inst Int Stat. 1960;28:233–243
PII: S0167-8140(09)00428-9
doi: 10.1016/j.radonc.2009.07.011