Radiotherapy & Oncology
Volume 93, Issue 1 , Pages 37-44 , October 2009

Fiducial-free real-time image-guided robotic radiosurgery for tumors of the sacrum/pelvis

  • Alexander Muacevic

      Affiliations

    • European Cyberknife® Center Munich, Munich, Germany
    • Corresponding Author InformationCorresponding author. Address: Director Cyberknife® Center Munich, European Cyberknife Center Munich, Max-Lebsche-Platz 31, 81377 Munich, Germany.
  • ,
  • Christian Drexler

      Affiliations

    • European Cyberknife® Center Munich, Munich, Germany
  • ,
  • Markus Kufeld

      Affiliations

    • European Cyberknife® Center Munich, Munich, Germany
  • ,
  • Pantaleo Romanelli

      Affiliations

    • IRCCS Neuromed, Pozzilli, Italy
  • ,
  • Hans Juergen Duerr

      Affiliations

    • Department of Orthopedic Surgery, University Hospital of Munich, Munich, Germany
  • ,
  • Berndt Wowra

      Affiliations

    • European Cyberknife® Center Munich, Munich, Germany

Received 2 September 2008 ,Revised 15 May 2009 ,Accepted 27 May 2009.

References 

  1. Lopez MJ, Luna-Perez P. Composite pelvic exenteration: is it worthwhile?. Ann Surg Oncol. 2004;11:27–33
  2. Degen JW, Gagnon GJ, Voyadzis JM, et al. Cyberknife stereotactic radiosurgical treatment of spinal tumors for pain control and quality of life. J Neurosurg Spine. 2005;2:540–549
  3. Gerszten PC, Ozhasoglu C, Burton SA, et al. Cyberknife frameless stereotactic radiosurgery for spinal lesions: clinical experience in 125 cases. Neurosurgery. 2004;55:89–98
  4. Gerszten PC, Germanwala A, Burton SA, Welch WC, Ozhasoglu C, Vogel WJ. Combination kyphoplasty and spinal radiosurgery: a new treatment paradigm for pathological fractures. J Neurosurg Spine. 2005;3:296–301
  5. Gerszten PC, Burton SA, Ozhasoglu C, Welch WC. Radiosurgery for spinal metastases: clinical experience in 500 cases from a single institution. Spine. 2007;32:193–199
  6. Ryu SI, Chang SD, Kim DH, et al. Image-guided hypo-fractionated stereotactic radiosurgery to spinal lesions. Neurosurgery. 2001;49:838–846
  7. Muacevic A, Staehler M, Drexler C, Wowra B, Reiser M, Tonn JC. Technical description, phantom accuracy, and clinical feasibility for fiducial-free frameless real-time image-guided spinal radiosurgery. J Neurosurg Spine. 2006;5:303–312
  8. Gerszten PC, Ozhasoglu C, Burton SA, et al. Cyberknife frameless single-fraction stereotactic radiosurgery for tumors of the sacrum. Neurosurg Focus. 2003;15:E7
  9. Xu F, Wang J, Bai S, et al. Detection of intrafractional tumour position error in radiotherapy utilizing cone beam computed tomography. Radiother Oncol. 2008;89:311–319
  10. Létourneau D, Wong JW, Oldham M, et al. Cone-beam-CT guided radiation therapy: technical implementation. Radiother Oncol. 2005;75:279–286
  11. Ho AK, Fu D, Cotrutz C, et al. A study of the accuracy of Cyberknife spinal radiosurgery using skeletal structure tracking. Neurosurgery. 2007;60:147–156
  12. Adler JR, Chang SD, Murphy MJ, Doty J, Geis P, Hancock SL. The Cyberknife: a frameless robotic system for radiosurgery. Stereotact Funct Neurosurg. 1997;69:124–128
  13. Kuo JS, Yu C, Petrovich Z, Apuzzo ML. The Cyberknife stereotactic radiosurgery system: description, installation, and an initial evaluation of use and functionality. Neurosurgery. 2003;53:1235–1239
  14. Murphy MJ, Chang SD, Gibbs IC, et al. Patterns of patient movement during frameless image-guided radiosurgery. Int J Radiat Oncol Biol Phys. 2003;55:1400–1408
  15. Welch WC, Gerszten PC. Accuray Cyberknife image-guided radiosurgical system. Expert Rev Med Devices. 2005;2:141–147
  16. Yu C, Main W, Taylor D, Kuduvalli G, Apuzzo ML, Adler JR. An anthropomorphic phantom study of the accuracy of Cyberknife spinal radiosurgery. Neurosurgery. 2004;55:1138–1149
  17. Fu D, Kuduvalli G. Enhancing skeletal features in digitally reconstructed radiographs. In: Reinhardt JM, Pluim JP, editors. San Diego, CA: SPIE Medical Imaging: Image Processing, SPIE; 2006, 6144-92, SP1.
  18. Fu, D, Kuduvalli, G, Maurer, CR, et al. 3D target localization using 2D local displacements of skeletal structures in orthogonal X-ray images for image-guided spinal radiosurgery. Computer assisted radiology and surgery, vol. 1. Berlin: Springer-Verlag; 2006. p. 198–200.
  19. Murphy MJ. The importance of CT slice thickness in radiographic patient positioning for radiosurgery. Med Phys. 1999;26:171–175
  20. Chang SD, Main W, Martin DP, Gibbs IC, Heilbrun MP. An analysis of the accuracy of the Cyberknife: a robotic frameless stereotactic radiosurgical system. Neurosurgery. 2003;52:140–146
  21. Gerszten PC, Ozhasoglu C, Burton SA, et al. Evaluation of Cyberknife frameless real-time image-guided stereotactic radiosurgery for spinal lesions. Stereotact Funct Neurosurg. 2003;81:84–89
  22. Keegan JJ. Alterations of the lumbar curve related to posture and seating. J Bone Joint Surg Am. 1953;35:589–603

PII: S0167-8140(09)00273-4

doi: 10.1016/j.radonc.2009.05.023

Radiotherapy & Oncology
Volume 93, Issue 1 , Pages 37-44 , October 2009