Radiotherapy & Oncology
Volume 90, Issue 1 , Pages 60-65, January 2009

Significance of breast boost volume changes during radiotherapy in relation to current clinical interobserver variations

Catharina Hospital, Department of Radiation Therapy, Eindhoven, The Netherlands

Received 13 July 2007; received in revised form 29 November 2007; accepted 6 December 2007. published online 21 January 2008.

Abstract 

Background and purpose

Nowadays, many departments introduce CT images for breast irradiation techniques, aiming to obtain a better accuracy in the definition of the relevant target volumes. However, the definition of the breast boost volume based on CT images requires further investigation, because it may not only vary between observers, but it may also change during the course of treatment. This study aims to quantify the variability of the CT based visible boost volume (VBV) during the course of treatment in relation to the variability between observers.

Materials and methods

Ten patients with stage T1–2 invasive breast cancer treated with breast conservative surgery and post surgical radiotherapy were included in this study. In addition to the regular planning CT which is obtained several days prior to radiotherapy, three additional CT scans were acquired 3, 5 and 7 weeks after the planning CT scan. Four radiation oncologists delineated the VBV in all scans. Conformity of the delineations was analysed both between observers, and between scans taken at different periods of the radiotherapy treatment.

Results

The VBV averaged over all patients decreased during the course of the treatment from an initial 40cm3 to 28cm3, 27cm3 and 25cm3 after 3, 5 and 7 weeks, respectively. Assuming the VBV to be spherical, this corresponds to a reduction in diameter of 5–6mm. More detailed analysis revealed that this reduction was more pronounced when radiotherapy started within 30 days after surgery. These boost volume changes over time were found to be significant (p=0.02) even in the presence of interobserver variations. Moreover, the conformity index (CI) for the volume changes was of the same magnitude as the conformity index for the interobserver variation (0.25 and 0.31, respectively).

Conclusions

Breast boost volume variations during a course of radiotherapy are significant in relation to current clinical interobserver variations. This is an important finding to take into account when introducing CT based planning, especially when applying an integrated boost technique.

Keywords: Breast cancer, Interobserver variation, Integrated boost, Boost volume changes, Treatment planning, Adaptive radiotherapy, Partial breast irradiation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0167-8140(07)00653-6

doi:10.1016/j.radonc.2007.12.001

Radiotherapy & Oncology
Volume 90, Issue 1 , Pages 60-65, January 2009